SYSTEMKAN-therm
Range of diameters 12-108 mm
Application
copper
pipes

System KAN‑therm Copper includes only fittings. Therefore, the pipes used with the system must meet specific requirements and have suitable properties.

Copper pipes used with KAN-therm Copper must be compliant with EN 1057 R220/R250/R290.
The values in the table refer to the tensile strength (220, 250 and 290N/mm²). There is a differentiation between soft, medium-hard and hard pipes – R220, R250 and R290 respectively. The higher the value, the harder the pipe material.
|
Copper pipes approved for using with the System KAN-therm Copper | ||||||||||
|
Ø [mm] |
Wall thickness [mm] | |||||||||
|
0,6 |
0,7 |
0,8 |
0,9 |
1,0 |
1,1 |
1,2 |
1,5 |
2,0 |
2,5 | |
|
12 |
R250 |
R220 | ||||||||
|
15 |
R250 |
R220 R250 R290 | ||||||||
|
18 |
R250 R290 | |||||||||
|
22 |
R250 |
R250 R290 |
R220 | |||||||
|
28 |
R250 |
R290 |
R250 |
R290 | ||||||
|
35 |
R290 |
R250 R290 |
R290 | |||||||
|
42 |
R290 |
R250 R290 |
R290 | |||||||
|
54 |
R290 |
R250 R290 |
R290 | |||||||
|
66,7 |
R250 R290 |
R290 | ||||||||
|
76,1 |
R250 R290 |
R290 | ||||||||
|
88,9 |
R290 | |||||||||
|
108 |
R250 R290 |
R290 | ||||||||